Walchem’s Ethernet Networking allows you to leverage the power of the WebMasterONE communications abilities. By
using the Local Area Network (LAN) or by connecting the WebMasters together via Ethernet, you can access all the con-
trollers on the network from a single phone line. It’s simple. Each controller includes Ethernet and the Master controller re-
quires the Ethernet Networking “Master” capability. Utilizing a Master-Slave type relationship - one controller is configured
to be the Master or window to all the other units (Slaves) on the network.
By utilizing the existing LAN, wiring can be minimized. The controller simply plugs into the nearest LAN connection via a
standard Ethernet cable. The Master controller detects the other Walchem devices on the network and provides a single
point of access.
Modbus TCP/IP (Ethernet) is available to seamlessly connect to building energy management, distributed control, process
management and SCADA systems.
ONE simple and flexible controller for ALL your water treatment needs!
Walchem’s WebMasterONE integrates advanced sensing,
instrumentation, fluid handling, and data communications
technologies to bring you the most sophisticated cooling
tower & boiler controller in the water treatment industry.
The simple, intuitive programming makes it easy to configure
your WebMasterONE to control multiple cooling towers,
boilers, closed loops, or virtually any water treatment process.
It will monitor and control based on a wide range of direct
sensor inputs as well as measurement inputs from other devices such as corrosion, level, temperature and
pressure.
WebMasterONE is on duty 24 hours a day, 365 days a year, keeping on-site and off-site personnel notified
of system performance, all the while providing comprehensive and reliable water treatment control.
Extensive built-in Plug & Play communications options:
Ethernet USB(laptop&flashdisksupport)
•Cellmodem •Landlinemodem
Easy to start-up and use - with just a web browser!
VTouch
®
provides quick, centralized 24/7 awareness of account status with the ability to LIVE Connect to any
of your controllers in the field with one simple mouse-click.
System status reports and datalog files can be sent automatically
Instant alarm notification via email, cell phone text message or local alarm relay
PPM set points with feed verification
Wide range of direct sensor measurements:
• pH •ORP
• Conductivity •Electrodelessconductivity
Freechlorine/bromine Chlorinedioxide
Modbus read/write is available for seamless integration with building energy management, distributed control,
process management and SCADA systems
Protect the building’s infrastructure while conserving water, energy and chemicals
WMT8 SINGLE COOLING TOWER
A System Cond
0 = No sensor
1 = Graphite electrode, 150 psi
2 = Electrodeless, 150 psi
3 = SS electrode, 150 psi
4 = High pressure, 300 psi
B pH/ORP
0 = None
1 = pH, flat, 100 psi
2 = ORP, rod, 100 psi
3 = Both, 100 psi
4 = pH, bulb, high pressure, 300 psi
5 = ORP, high pressure, 300 psi
6 = Both, 300 psi
C Makeup Cond
0 = None
1 = Graphite electrode
2 = Electrodeless
3 = SS electrode
4 = High pressure, 300 psi
WMB8 BOILER
A Boiler #1 Conductivity Sensor
0 = None
1 = 250 psi
B Boiler #2 Conductivity Sensor
0 = None
1 = 250 psi
C Boiler #3 Conductivity Sensor
0 = None
1 = 250 psi
D Boiler #4 Conductivity Sensor
0 = None
1 = 250 psi
WMD8 DUAL COOLING TOWER
Tower #1(A) and Tower #2 (C) System Conductivity
0 = No electrode
1 = Graphite electrode
2 = Electrodeless
3 = SS electrode
4 = High pressure
Tower #1 (B) and Tower #2 (D) 2nd Sensor
0 = No sensor
1 = pH, flat
2 = ORP, rod
3 = pH, High pressure
4 = ORP, High pressure
5 = Contacting cond, graphite
6 = Contacting cond, high pressure
WM18 MIXED PURPOSE
A number of sensor inputs requried
1 = One sensor input
2 = Two sensor inputs
3 = Three sensor inputs
4 = Four sensor inputs
180275.J1 Aug 2013
WMT8
B C EA F G H J K
WMB8
B DC EA G H J K
WMD8
B DC EA F G H J K
WM18
EA G H J
K
Sensor Selection System Options
Single
Cooling Tower
Boiler
Sensor Selection
E VOLTAGE CODE (ALL MODELS)
0 = Prewired, 0 powered, 8 dry contact relays
1 = Prewired, 7 powered, 1 dry contact relays
2 = Prewired, 8 powered, 0 dry contact relays
3 = Prewired, 4 powered, 4 dry contact relays
4 = Hardwired, 0 powered, 8 dry contact relays
5 = Hardwired, 8 powered, 0 dry contact relays
6 = Hardwired, 7 powered, 1 dry contact relays
7 = Hardwired, 4 powered, 4 dry contact relays
F FLOW SWITCH OPTIONS (WMT & WMD ONLY)
N = No flow switch, in-line sensors
L = Loose flow switch manifold, 20 ft cable, low pressure
P = Flow switch manifold on PP panel, 5 ft cable, low pressure
S = No flow switch, submersion sensors
F = Loose flow switch manifold, 20 ft cable, high pressure
H = Flow switch manifold on PP panel, 5 ft cable, high pressure
C = Flow switch manifold on PP panel, 5 ft. cable, low pressure +
corrator, tee and sensor (no electrodes)
D = Flow switch manifold on PP panel, 5 ft. cable, low pressure +
Little Dipper, tee
E = Flow switch manifold on PP panel, 5 ft. cable, low pressure +
corrator, Little Dipper, sensors
G ANALOG OUTPUTS (ALL MODELS)
N = No analog outputs
1 - 4 = One to Four 4-20 mA output boards
H INPUT OPTIONS
N = No input options
A = 8 analog inputs
D = 6 digital inputs
B = Both analog and digital input cards
J COMMUNICATIONS HARDWARE
(USB & ETHERNET STANDARD)
N = No additional hardware
M = Landline Modem
G = GPRS Modem
K COMMUNICATIONS SOFTWARE
N = No additional software
1 = Ethernet networking master capability
2 = Modbus TCP/IP
3 = Both Ethernet networking and Modbus TCP/IP
System Options
Dual
Cooling Tower
Mixed Purpose
1
2
3
4
1
2
3
4
With an embedded web server, WebMasterONE utilizes standard TCP/IP Internet communications. Remote communications can
be established with WebMasterONE via the Internet or on a direct line with modem-to-modem capability. USB Plug and Play
and Ethernet are included to allow easy on-site access for plant personnel and system operators. Multiple users can access the
controller simultaneously. A graduated password protection system allows users varied degrees of access from view only to full
system configuration. In addition, WebMasterONE delivers a range of user-friendly information reporting tools including email
notifications for datalogs, alarms and system summaries.
Walchem has made use of the Internet as a remote access communications platform for industrial control equipment a practical
reality. While others just attempt to reduce the cost of embedded web server hardware, Walchem has solved the problem of the high cost
and lack of availability of a permanent connection to the Internet.
WebMasterONE makes programming your cooling tower or boiler simple and fast and WebMasterONE does not require any
proprietary software to reside on your computer. Set-up and programming are all done via a standard web browser. Easy to follow
menus and system set-up screens make programming user friendly and intuitive. Once WebMasterONE is installed, the Start-up
menu jump-starts you through the top level set-up. The Input, Output and utility menus guide you through the rest of the program-
ming.
• USB Plug and Play: For local monitoring and reconfiguration of
your WebMasterONE via LapTop or dedicated on-site PC.
• ShoulderTap® Internet Communications: For monitoring and
reconfiguration of your WebMasterONE remotely via the
Internet (requires landline modem card option).
• DirectTap Modem-to-Modem: For remote monitoring and
reconfiguration of your WebMasterONE using traditional modem-
to-modem communications (requires landline modem card option).
• Ethernet: For monitoring and reconfiguration of your WebMasterONE
via Local Area Network or remotely via the Internet
• Cellular: For monitoring and reconfiguration of your WebMasterONE
remotely via the Internet (requires cell modem and VTouch option).
ETHERNET NETWORKING
USB Plug & Play
Phone Company
Modem
Modem
Modem
Modem
Internet
Walchem Web Page
LAN
LAN
Internet
VTouch Web Page
Internet
Cell Service
provider
ISP
WebAlert®
Slave Unit
WebMasterONE
Master Unit
Internet
Email
LAN
LAN
LAN
LAN
LAN
LAN
LAN
WebMasterONE
Slave Units
LAN
WebMaster
®
ONE Controllers
Communications
Ordering
Information
Cooling Tower/Boiler Controllers
Summary of Key Benets
Vista de pagina 0
1 2 3 4 5 6

Indice de contenidos

Pagina 1 - ONE Controllers

Walchem, Iwaki America Inc. Five Boynton Road Hopping Brook Park Holliston, MA 01746 USA Phone: 508-429-1110 www.walchem.comWalchem’s Ethernet

Pagina 2 - Account

InnovationWebMasterONE is the most advanced online process controller in the water treatment industry. It supports all global communications standard

Pagina 3

InnovationWebMasterONE is the most advanced online process controller in the water treatment industry. It supports all global communications standard

Pagina 4

Walchem, Iwaki America Inc. Five Boynton Road Hopping Brook Park Holliston, MA 01746 USA Phone: 508-429-1110 www.walchem.comWalchem’s Ethernet

Pagina 5

InnovationWebMasterONE is the most advanced online process controller in the water treatment industry. It supports all global communications standard